Overview

The 4-Hour Emergency Light is designed to provide four hours of emergency illumination when AC power in the facility is lost. Underwriter Laboratories (UL), who are responsible for the UL 924 Standard for Emergency Lighting and Exit Sign Fixtures, require emergency fixtures to operate for a minimum of 90 minutes when powered by backup battery packs. The 4-Hour Emergency Light provides 240 minutes of emergency illumination for lighting applications where the bare minimum isn't enough. Common applications for this fixture include large-scale manufacturing facilities where rolling blackouts can occur and processing plants that take more than 90 minutes for power to be restored. 

The 4-Hour Emergency Light features a push button battery backup testing system and a powerful sealed lead acid battery that will provide four hours of emergency illumination. This fixture is UL 924 listed for use in the United States.

Features

  • Four hours of emergency illumination
  • 9 watt Halogen lamps
  • 20-gauge steel housing
  • Sealed lead acid battery and push button testing system
  • UL 924 listed for use in the United States

Application

The 4-Hour Emergency Light does just what its name implies: provides 240 minutes of emergency illumination. It is commonly used in large-scale processing and manufacturing facilities where the 90 minute minimum isn't enough.

External

The 4-Hour Emergency Light's housing is constructed from a rugged 20-gauge steel that comes standard in a baked white enamel powder coat. Top-mounted halogen lamps are easily adjustable to fit almost every lighting environment. 

It is also possible to order this fixture in a polycarbonate, waterproof housing, that will protect internal components from moisture, dust, and other hazardous elements. 

Internal

The 4-Hour Emergency Light uses 120V and 277V AC connections to power the fixture and charge the sealed lead acid battery. This fixture also uses a low voltage battery disconnect to prevent the battery pack from being damaged during long discharge periods, while the AC lockout feature prevents battery discharge when not in use. Custom voltages are available upon request.

Lamp Specifications

This fixture comes standard with two adjustable 9 watt Halogen lamp heads. These lamps provide brilliant illumination and almost double the output of typically used 5.4 watt lamp heads.

It is possible to outfit the 4-Hour Emergency Light with more powerful lamp heads for industrial emergency lighting applications. Photometric data is available for all lamp heads. 

The 4-Hour Emergency Light comes standard with two lamp heads, but can be customized to operate with one or even zero lamps. When outfitted with zero lamp heads, this emergency light is used as a power supply for remotely located lamp heads. Lamp wattages are available in 12, 18, 25, 30, 35, 55, and 70 watts.

Please call us at 800-480-0707 for pricing and availability of lamp head options.

Battery

The 4-Hour Emergency Light comes standard with a 6 volt 100 watt sealed lead acid battery that will provide 240 minutes of emergency illumination. Even higher capacity batteries are available to extend run time or support more powerful lamp heads. 

The sealed lead acid battery charges in 24 hours and can operate at temperatures up to 122º F. OSHA requires monthly and yearly tests of the backup battery system, which is quick and easy thanks to the push button testing system. The included battery is expected to last 3 to 5 years.

Options

To purchase a fixture with any of these options, please email us or call us at 800-480-0707 for pricing and availability.

  • Self-testing: visually displays integrity of internal components via LED lights.
  • Nickel-Cadmium (Ni-Cd) Battery: these batteries have a 5 to 7 year lifespan, are easy to replace, and are light.
  • Time-delay: installations that use fluorescent and high-intensity discharge (HID) lamps can take 15 minutes to reach full intensity after a momentary loss of power. A time delay option keeps emergency lights on while other lights require time to warm up.

Durability

The 20-gauge steel housing is durable and designed to withstand moderate abuse. It is possible to purchase fixtures with wet location housing, constructed of weatherproof polycarbonate housing, that are impervious to moisture, water, and dust. These fixtures are popular solutions for industrial environments that are known to feature elements that would cause standard emergency lights to malfunction.

Appeal

The 4-Hour Emergency Light extends the emergency run time of the battery from 90 minutes to 240 minutes. This allows for safe emergency egress and return to the facility even if AC power has not been restored within 90 minutes. 

Value

This fixture provides unparalleled run time while remaining affordable. All components are constructed from high quality components that are designed to meet safety codes and provide emergency illumination for years to come. 

Installation

The 4-Hour Emergency Light mounts to most nonflammable surfaces and features conduit knockouts on the back and sides of the fixture.